          Application of



          Solid-State Relay



          NSI7258 in Insulation



          Monitoring for



          High-Reliability BMS




          By Kaijie Zheng and Ning Zhang, Novosense



           The operating voltage of a battery management      insulation monitoring circuit should promptly detect
          system (BMS) generally exceeds the safe voltage     the change and trigger an alarm.
          threshold for the human body. A degradation in
          insulation performance may lead to increased leakage   The recommended insulation monitoring circuit
          current, posing a threat to personal safety. The    is illustrated in Figure 1. K  and K  represent the
                                                                                     1
                                                                                           2
          insulation monitoring circuit described in this article   main application positions of Novosense solid-state
          utilizes the NSI7258 from Novosense to calculate and   relays (SSRs) in the insulation monitoring circuit.
          monitor the insulation resistance between the positive   The chip adopts a low-side control approach, where
          bus-to-ground and negative bus-to-ground of the     the low-side reference ground is the vehicle chassis
          battery, thereby achieving high-precision and       ground. This circuit performs insulation resistance
          high-reliability insulation monitoring.             measurements (R , R ) every two to three seconds
                                                                                 n
                                                                              p
                                                              by switching K  and K , while K  switching controls
                                                                           1
                                                                                         3
                                                                                 2
          PRINCIPLE OF THE SOLUTION                           whether the insulation monitoring circuit is active.
           According to China’s national standard GB 18384,   During insulation monitoring, K  remains normally
                                                                                          3
          “Electric vehicles safety requirements,” the insulation   closed.
          resistance must be greater than 500 Ω/V at the
          maximum operating voltage. Therefore, for a system   In this article, the bus voltage is defined as V BUS , the
          with a bus voltage of V BUS , the insulation resistance   positive bus-to-chassis ground voltage as V , and the
                                                                                                     p
          must be greater than 500 × V BUS  to ensure personnel   chassis ground-to-negative bus voltage as V .
                                                                                                     n
          safety. When the insulation resistance degrades, the