Page 52 - PEN Ebook May 2021
P. 52

Design                                                                                                                                                                                                               Design


          defined as junction temperatures. Thus, active       Using the second equation from Table 1, the ac-

          and passive mode do not require differentiation.     celeration factor, and the second data point (45h)
          There are certainly aging effects that are related   of the mission profile in Table 2, the needed test
          to current densities when an IC is operating, but    time (tt) can be calculated with Equation (2):
          these effects are minor when compared to the
          aging effect of temperature.

          Using the Arrhenius equation from Table 1, enter
          the first data point (-40°C) of the mission profile
          in Table 2. With a test temperature of 125°C, the

          acceleration factor (Af) can be calculated with                                         (2)
          Equation (1):
                                                               That means the real-life stress represented by
                                                               -40°C over 45h would be equal to an HTOL test for
                                                               just a fraction of an hour at 125°C (see Table 2). In
                                                       (1)     order to calculate the total mission profile stress,
                                                               all data points of the mission profile must be cal-

                                                               culated similarly, and the related equivalent test
                                                               times must sum to a total of about 5888h. That


                                                                                                                                 Figure 4: Flowchart A7.2 of AEC-Q100 Rev. H Standard.


                                                                                                                                 means that in the real world, the device will receive   by bringing down the junction temperature via
                                                                                                                                 stresses that are 6 times greater than the stresses   heatsinking measures), the qualification should
                                                                                                                                 it received under testing conditions.                be adjusted.



                                                                                                                                 To pass an HTOL test of 1000h means that the         Using this example, do the HTOL qualification at
                                                                                                                                 device can withstand at least 1000 hours of stress.   an increased T  of 150°C. The test time needed to
                                                                                                                                                                                                   J
                                                                                                                                 However, this does not guarantee how much longer     cover the mission profile stress in this scenario
                                                                                                                                 past 1000h that the device can withstand the stress.   is reduced to about 1767h. Note that even higher
                                                                                                                                 Given that the equivalent stress is 6 times higher   junction temperatures are not possible, as 150°C is
                                                                                                                                 than the qualification stress, there is certainly some   typically the absolute maximum temperature that
                                                                                                                                 concern that premature failures may occur.           silicon can be subjected to without being dam-

                                                                                                                                                                                      aged. That being said, the test time for this exam-
                                                                                                                                 This is why automotive electronics reliability       ple would need to be extended to about. 2,000
                                                                                                                                 testing is crucial and devices must be able to       hours to be on the very safe side. However, even
                                                                                                                                 withstand high levels of stress. Figure 3 shows      1,500 hours of qualification test time can provide
                                                                                                                                 Monolithic Power Systems (MPS) devices under-        a fair level of confidence, and can be a reasonable
                                                                                                                                 going an HTOL test.                                  tradeoff relative to testing costs and time.


                                                                                                                                 In case the mission profile cannot be relaxed

          Figure 3: MPS Devices Under HTOL Test Operate Under Load Conditions.                                                   (e.g. the associated stress cannot be reduced

  52      MAY 2021 | www.powerelectronicsnews.com                                                                                                                                              MAY 2021 | www.powerelectronicsnews.com      53
   47   48   49   50   51   52   53   54   55   56   57