Power Supply



            The inverter switching losses P     were modeled by means of an equivalent current source in
                                            sw,inv
            parallel to the inverter input, whose current is given by:









            The Tx and Rx conduction losses are given by:






            The overall WPTS efficiency is evaluated as:










            EXPERIMENTAL VERIFICATION OF WPTSes

            The  WPTS  adopted  for  the  validation  of  the  proposed  model  is  characterized  by  the  following
            operating  parameters:  f   =  6.78  MHz,  L   =  7.5  μH,  L   =  0.93  μH,  C   =  1  ÷  (ω   ×  L )  =  73.5  pF,
                                                                                           2
                                    s               1            2              1s         s    1
            C  = 1 ÷ (ω  × L ) = 593 pF, Q  = 150, Q  = 40, Q  = Q  = 1,000. The WPTS is physically realized with
                       2
              2s       s    2            L1       L2       C1   C2
            the Tx coil (nine turns, 70 × 70-mm  diameter) and the Rx coil (eight turns, 15 × 15-mm  diameter).
                                                                                                 2
                                               2
            The Rx coil was placed centered with respect to the Tx coil at 6 mm of distance from each other,
            yielding a coupling factor of K = 0.076 (calculated by means of Ansys’s high-frequency structural
            simulator). Rohm’s RUF015N02 MOSFETs were adopted for the inverter and rectifier stages. Texas