Page 12 - PEN eBook December 2022
P. 12

DESIGN












































                                                                                                                                   Transformerless



                                                                                                                                   Fast-Charging



                                                                                                                                   Solutions for PEVs





                                                                                                                                   By Stefano Lovati, technical writer for EEWeb




                                                                                                                                   In a plug-in electric-vehicle (PEV) system, chargers can be classified into three levels: AC Level
                                                                                                                                   1 (<1.92 kW), AC Level 2 (<19.2 kW), and DC Level 3 (>19.2 kW). Due to their volume and weight,
                                                                                                                                                                                                  1
                                                                                                                                   on-board chargers are not recommended in high-power Level 3 systems.


                                                                                                                                   This article will propose two topologies for off-board non-isolated DC fast chargers with power up

                                                                                                                                   to 22 kW. The typical block scheme of this charger includes an AC/DC rectifier stage, followed by a
                                                                                                                                   DC/DC converter. The AC/DC stage is usually implemented using a single-phase or a three-phase
                                                                                                                                   application,  depending  on  the  grid  requirements.  The  three-phase  option  provides  the  benefit
                                                                                                                                   of sharing the same hardware for both the grid interface and the DC/DC stage. Read the original
                                                                                                                                   article here.