        Smartphone Sensor Gauges Blood Pressure with Clinical Accuracy


                                                                                and diagnostic support on a server to store
                                                                                the data. All three parts will comply with all
                                                                                CE, FDA, and CFDA regulatory requirements
                                                                                for a Class IIA/Class II medical device as well
                                                                                as all relevant privacy regulations.
                                                                                  The V-Sensor has a pressure sensor embed-
                                                                                ded in a soft, flat epoxy resin that is pressed
                                                                                against the fingertip. LEDs and a photodiode
                                                                                form a conventional pulse oximeter that
                                                                                illuminates the tip of the finger. A thermopile
                                                                                measures heat radiation to estimate body
        Hardware setup (Image: Leman Micro Devices)                             temperature. The application-specific inte-
                                                                                grated circuit designed by LMD controls the
        happen during the day. According to proponents of the emerging tech-  LEDs; captures and digitizes data from the photodiode, pressure sensor,
        nologies, the continuous monitoring of biomedical parameters would   and thermopile; and communicates with the mobile-phone processor.
        encourage people to adopt and sustain healthy behaviors, with a view   The V-Sensor can integrate into the back of a smartphone and is
        to promoting health and preventing disease.           curved to fit a fingertip. It offers a comfortable and ergonomic user
          The solution offered by LMD uses innovative sensor technology to   experience. To measure blood pressure, the user simply holds the
        measure blood pressure, temperature, and pulse and even perform   phone in a natural grip, with the index finger on the V-Sensor recessed
        ECG functions, recording the electrical activity of the heart. The blood   on the back of the phone and the thumb on the front screen. The
        pressure measurement uses the Riva-Rocci procedure.   e-Checkup app guides the user to play with the display by pressing
          Blood pressure is the pressure exerted by the blood, pumped from   harder or softer. A measurement takes approximately one minute. No
        the heart, on the wall of the arteries that distribute blood in the body.   external devices are required; an e-Checkup–enabled smartphone pro-
        The blood pressure in the arteries can be measured directly by intro-          vides the complete solution.
        ducing a small tube (catheter) into the artery itself and connecting it to       The app is the interface between
        a measuring device (pressure transducer). In practice, this happens only       the phone’s operating system and
        in special circumstances, such as during surgery.                              LMD’s V-Sensor. It takes care of all
          The common blood pressure measurement, on the other hand, is                 the processing, including obtaining
        carried out indirectly, using special devices that are able to assess the      the V-Sensor features from LMD’s
        blood pressure from outside, in a non-invasive way. Of these devices,          database the first time it is used.
        the most precise and commonly used so far is the one designed by               Blood pressure accuracy is within
        Riva-Rocci just over a century ago. It consists of a rubber bracelet           the scope of ISO 81060-2, which
        connected on one side to a small hand pump and on the other to a               for the main criterion is an average
        mercury column pressure gauge. Because the instrument was equipped             error of <5 mmHg and <8-mm stan-
        with a glass column containing mercury and bearing a gauge indicating          dard deviation.
        the distance expressed in millimeters, the unit of measurement with              All measurements can be taken
        which the maximum and minimum blood pressure values are reported               anywhere, anytime, in less than 60
        is millimeters of mercury (mmHg).                                              seconds by following the on-screen
          Body temperature, meanwhile, is traditionally measured using an              instructions and without the need
        infrared forehead scan with environmental conditions, as first used            for special accessories or prior
        in 1835. ECG information can be obtained from a transducer placed              calibration.
        between the hands. Finally, traditional measurements of pulse rate,              The sensor in question (a tiny,
        blood oxygen (SpO ), and respiratory rate are all based on established         15-mm-long device to be placed
                      2
        pulse oximetry transducers with established technology, in use since           on the back of a smartphone) not
        1972. Respiratory rate is derived from heart rate and amplitude modu-          only allows you to measure blood
        lation (respiratory sinus arrhythmia).                                         pressure but, according to LMD,
          “We have combined established, mature science with modern                    allows you to obtain accurate
        technology,” said Chris Elliott, founder and director of Leman Micro           measurements of body tempera-
        Devices SA. “That gives users and their doctors measurements that   Smartphone with V-sensor   ture, oxygen saturation (a measure
        they understand and know that they can trust with the convenience of   (Image: Leman Micro Devices)  of pulmonary function), heart rate,
        a medical-grade device with them at all times.                                 and breathing speed.
          “For example, we measure blood pressure using exactly the same   LMD’s research and development have shown that V-Sensor data can
        science as a cuff around your arm, but we make it easier, smaller, and   be combined with accelerometer data in the phone when held against
        cheaper by using the fingertip and by getting the user to press harder or   the chest to find the timing of the heart function: left ventricular
        softer rather than having a heavy and expensive pump and cuff,” Elliott   expulsion time (LVET), aortic and mitral valve timing, and many others.
        added.                                                Further measurements may combine images from the phone’s camera.
          He explained that high blood pressure (hypertension) is a “silent   A health economist developed a Markov model using empirical data
        killer” with no symptoms, so putting a cuffless and calibration-free   to estimate the health impact of buying a phone that measures blood
        blood pressure meter into every phone could save the lives of many of   pressure. He showed that, on average, a young user would gain about
        the 9 million people who die from it every year.      six months of life, while an older user would gain about three months
                                                              of life. ■
        THE TECHNOLOGY
        LMD’s technology consists of its V-Sensor hardware module and   Maurizio Di Paolo Emilio is a staff correspondent at AspenCore,
        e-Checkup software algorithm to instruct the user and analyze the data   editor of Power Electronics News, and editor-in-chief of EEWeb.